 ECLER TECHNICAL DATA SHEET




AURA-8L150
COMMERCIAL AMPLIFIERS
Multichannel LoZ Amplifier




PRODUCT OVERVIEW
 AURA-8L150 is a multichannel, 8x150 W RMS @ 4 Ω, high efficiency amplifier (class D). AURA Series are built with
 the highest robustness for long lasting performances with special power supply circuitry designed for optimized
 electrical consumption and are 100% silent featuring convection cooling system. AURA Series also features the
 possibility of linking channels to the first input by selecting it on the rear panel, adjustable Auto Standby level, overload
 and thermal protection, PFC and anti-clipping system.




KEY FEATURES                                                          APPLICATIONS
 • 8 analogue audio inputs and 8 x150 WRMS @ 4 Ω                       • Leisure
  powered audio outputs.                                               • Hospitality
 • Euroblock input and output connectors.                              • Education
 • Link to input 1 available.                                          • Corporate
 • Volume control knobs on front panel, that can be blocked            • Sports & Wellness
  via switches accessible from the bottom cover.                       • Retail
 • High efficiency (Class D).
 • Auto Standby function.
 • Convection cooling (fanless, 100% silent).
 • Thermal protection.
 • Overload protection.
 • Anti-clip system.




             96-0028-0100                               AURA-8L150                                             EN                1
 ECLER TECHNICAL DATA SHEET


TECHNICAL SPECIFICATIONS

   AURA-8L150
   INPUTS
                       Number of Inputs      8
       Analogue input connection type        3-pin Euroblock, balanced, pitch 3,5 mm
                      Input configuration    Input link to CH1 selector per input
    AMPLIFIED OUTPUTS
             Number of amplified outputs     8
      Amplified output connection type       2-pin Euroblock. Pitch: 5 mm
    OUTPUT POWER         All channels driven @ 1%THD
                Max output power @ 8Ω        75W
                Max output power @ 4Ω        150W
    SIGNAL
                            Voltage gain     27,8 dB
                         Input sensitivity   0 dBV
                                             2,21 dBu
                                             1 Vrms
                        Input impedance      >500kΩ (balanced)
                         Max input level     +12dBV
                                             14,21 dBu
                    Frequency response       15Hz-30kHz (-3dB, 1W @ 4Ω)
                            THD + Noise      < 0,01 % (from 1W to full power output @ 4Ω)
                                     SNR     100 dBA (from 20Hz - 20kHz)
                               Crosstalk     >80dB (@ 1kHz)
                                  CMRR       > 55 Typ (from 20Hz-20kHz)
                         Damping factor      >150 (DF @ 8 Ω, 20 Hz - 400 Hz)
    ELECTRICAL
                           Power supply      Universal, regulated SMPS with PFC
                  AC mains requirement       100-240 V @ 50-60Hz (±10%)
                 Power factor correction     > 0,92 (Output Power > 1/4 Max Output Power)
                    AC mains connector       IEC C14 inlet (10Amax, Power cord 10Amax)
    POWER & HEAT @230VAC
                    1/4 POWER, @ 4Ω (all channels driven)
                                  Power      391,8 W | 424,9 VA
                           Current Draw      1,853 Arms
                           Thermal Loss      79,29 kcal/h | 314,68 BTU/h
                    1/8 POWER, @ 4Ω (all channels driven)
                                  Power      217,7 W | 246,3 VA
                           Current Draw      1,073 Arms
                           Thermal Loss      58,08 kcal/h | 230,51 BTU/h




                                                                                            2
ECLER TECHNICAL DATA SHEET


                 IDLE (all channels driven)
                               Power      34,6 W | 66,9 VA
                        Current Draw      0,291 Arms
                        Thermal Loss      29,76 kcal/h | 118,09 BTU/h
                 SLEEP MODE (all channels driven)
                               Power      24,0 W | 54,5 VA
                        Current Draw      0,237 Arms
                        Thermal Loss      20,64 kcal/h | 81,91 BTU/h


  POWER & HEAT @120VAC
                 1/4 POWER, @ 4Ω (all channels driven)
                               Power      400,8 W | 408,5 VA
                        Current Draw      3,592 Arms
                        Thermal Loss      86,96 kcal/h | 345,12 BTU/h
                 1/8 POWER, @ 4Ω (all channels driven)
                               Power      221,9 W | 227,6 VA
                        Current Draw      1,992 Arms
                        Thermal Loss      61,70 kcal/h | 244,85 BTU/h
                 IDLE (all channels driven)
                               Power      34,7 W | 41,47 VA
                        Current Draw      0,361 Arms
                        Thermal Loss      29,84 kcal/h | 118,43 BTU/h
                 SLEEP MODE (all channels driven)
                               Power      24,36 W | 31,9 VA
                        Current Draw      0,278 Arms
                        Thermal Loss      20,95 kcal/h | 83,14 BTU/h
  TECHNOLOGIES
           Amplification technology       Class D
                        Energy saving     Auto Standby function selectable (Auto Standby by pairs of
                                          channels)
                            Efficiency    76% (1/4 POWER, @ 4Ω, 230VAC)
                              Cooling     Convection (fanless)
   PROTECTIONS
                        DC protection     Yes
                        HF protection     Yes
            Short-circuit protection      Yes
                           Clip limiter   Yes
                   Thermal protection     Yes
  LOCAL CONTROL
                          Attenuators     Front panel knobs per channel
                                          VOL (default)/BYPASS option) (VOL/BYPASS selectable by a
                                          switch at the bottom)




                                                                                                       3
ECLER TECHNICAL DATA SHEET


                   RUN/SLEEP mode       Auto Standby function
                                        Front panel button
                                        (Auto Standby ON/OFF button per unit. -50dB (default) or -40dB,
                                        internally selectable. Auto stand-by time: 60 seconds)
                      Power ON/OFF      Front panel switch (green LED indicator)
  MONITORING
                      Signal Present    SIGNAL LED (Green) per channel (trigger @- 40 dBV)
                            Clipping    CLIP LED (Red) per channel
                             Protect    PROT LED (Red) by pairs of channels (Combined PROT/TH LED)
                            Standby     AUTO STANDBY ON/OFF LED (Green) per unit
                      Standby / Mute    AUTO STANDBY (Orange) by pairs of channels
                             Thermal    TH LED (Orange) by pairs of channels (combined PROT/TH LED)
                                 On     ON LED (Green) per unit
                                Link    LINK LED (White) per channel
  PHYSICAL
               Operating temperature    -10º to 50º C
                                        14º to 122º F
                  Operating humidity    5 - 85% RH, non-condensing
                Storage temperature     -10º to 50º C
                                        14º to 122º F
                    Storage humidity    5 - 85% RH, non-condensing
                 Included accessories   Rear rack support
               Dimensions (WxHxD)       482.6x44x414 mm. / 19x1.73x16.29 inches
                             Weight     6.3 kg / 13.9 lb
      Shipping dimensions (WxHxD)       590x75x585mm. / 23.23x2.95x23.03 inches
                     Shipping weight    8.35kg / 18.41lb




                                                                                                          4
ECLER TECHNICAL DATA SHEET


MECHANICAL DIAGRAM




                             5
  ECLER TECHNICAL DATA SHEET


A & E SPECIFICATIONS
The Amplifier shall be a constant voltage 100 V type, containing eight independent controllable amplifier channels with
a 150W maximum output power per channel. The construction shall be transformer-less, using Class-D Amplifier
technology and powered by a universal, regulated SMPS with PFC power supply. Each channel shall have integrated
circuitry to protect against short-circuits or mismatched loads and over-heating. Additionally, the load shall be protected
against DC faults and a clip limiter shall automatically reduce the input gain at onset of distortion.

The front panel shall contain an AC power switch, a power on indicator LED, an Auto Standby button and Auto Standby
LED. Each channel should have a level knob, a signal LED, a clip LED and a link LED, moreover protect and thermal
LEDs for each pair of channels. The front panel knobs should be able to be disabled by means of the VOL Bypass
switches -accessible with a thin screwdriver- from the bottom face of the chassis. Auto Standby threshold should be
selectable, for every 2 adjacent channels, by means of an internal jumper, between -40db / -50 dB values. The possibility
to link the channels to input 1 shall be available through a button on the rear panel.

All connections shall be made on the rear panel of the unit. The output connections must be fitted with terminal block
connectors. The amplifier shall operate on a 100-240V AC - 50/60 Hz mains network and shall be equipped with a
removable power cord having a standard Shuko (CEE 7/7) AC plug. The connector on the amplifier chassis shall be a
fused IEC C14 type. The amplifier chassis shall be a 1UR steel constructed 19’’ housing. Depth from mounting surface
to rear supports shall be 414 mm and the weight shall not exceed 6.3 Kg.

The amplifier shall be the ECLER AURA-8L150.




All  product     characteristics    are    subject      to  variation due to production tolerances.
NEEC AUDIO BARCELONA S.L. reserves the right to make changes or improvements in the design or
manufacturing that may affect these product specifications.
For technical queries contact your supplier, distributor or complete the contact form on our website,
in Support / Technical requests.
Motors, 166‐168 - 08038 Barcelona - Spain | (+34) 932238403 | information@ecler.com | www.ecler.com                           6


Texte extrait tel quel de la pièce officielle, qui seule fait foi. La mise en page du document d'origine peut différer.